Detail OVAL FLOWMETER FLOWPET-NX LS5676-2OOA
OVAL FLOWMETER FLOWPET-NX LS5676-2OOA
OVAL FLOWMETER FLOWPET-NX LS5676-2OOA
GENERAL
Flowpet-NX is an OVAL flowmeter primarily developed
for fuel oil meansurement.
Field proven for consistent metering accuracy and long life
combined with its ease of use and economy make this
industrial instrument ideally suited for heat control appli
cation as a dedicated flowmeter
FEATURES
1.Mechanical register equipped model is also available
which requires no power source for oil service.
2.Can furnish reliable pulses to a total counter and a high
speed pulse output to a flow indicator
General Specifications
Flow Range
Model : LS5676-2OOA
Nominal Size ( mm) : 50
Flange Rating : JIS 10K RF
Flow Range , L/ h
Kerosene : 2000 to 20000
( Above 0.8mPa• s to 2mPa• s)
Gas Oil ( Heavy oil A) : 1400 to 24000
( Above 2mPa• s to 5mPa• s)
Heavy Oil : 900 to 24000
( Above 5mPa• s to 200mPa• s)
Meter Body
Acceptable flulds : Kerosene, Light oil, Heavy Oil ( Not serviceable with gasoline)
Operating temp . Range ( fluid temp.) : 0 to 120pC
Max.operating pressure : 1.18MPa
Linearity : ± 0.35% of RD
Material
Body : FC250
Rotors : Special resin
Flow direction : Right ’ Left ( standard) , Left ’ right, bottom ’ top, top ’ bottom
Coating color : Orange : Munsell 2.5 YR 6/ 13
Mechanical Register Specifications
Model : LS5676
Functions : Cumulative counter with dial-and-pointer, 6 digits number wheels
Display
One pointer rev : 10 L
Resolution : 0.1L
Counter capacity : 9, 999, 999.9L
Output Pulse : See next section
Operating Temp Range : -10 to + 60pC
Construction : Waterproof conforming to IP 65 ( weathertight)
Material : Resin/ Alumunium die casting
Finish ( houshing) : Munsell 4.9 PB4.0/ 13.9 ( Color of molding)
Factored Pulse generator in Mechanical Register ( optional)
Item : MR sensor
Type of output pulse : Voltage pulse/ open collector
Number of pulses ( per pointer rev.) : 10 P
Pulse Width : 1 ms min
Duty factor :
Output Signal Levels : Voltage pulse ON: 6.5V min OFF : 1 V max
Open Collector ON: 1V max
Max.Operatiing Current : 30mA
Max.Operating Voltage : 40V DC ( OPEN COLLECTOR)
Contact Bounce :
Life :
Signal Cable : Vinyl-insulated, 4-conductor, shielded ( core wire 0.5mm² , 4 to 10mm in O.D)
Transmission Distance : 1 Kilometer max.( using a CVVS cable 1.25 to 2.0mm² )
Power : 12 to 24VDC ± 10%
Current Drain : 20mA max
Item : Reed switch
Type of output pulse : Contact-closure pulse
Number of pulses ( per pointer rev.) : 1 P
Pulse Width :
Duty factor : 40/ 60 to 60/ 40
Output Signal Levels :
Max.Operatiing Current : 60mA ( 200© protective resistor provided)
Max.Operating Voltage : 125V AC, 50V DC
Contact Bounce : 0.5ms max
Life : 5 x 10w cycles off operating ( with resistive load at 12V DC, 10mA)
Signal Cable : Vinyl-insulated, 4-conductor, shielded ( core wire 0.5mm² , 4 to 10mm in O.D)
Transmission Distance : 1 Kilometer max.( using a CVVS cable 1.25 to 2.0mm² )
Power :
Current Drain :
Mechanical Register Pulse Output
Model : LS5676-2OOA
Nominal Size ( mm) : 50
MR Sensor
Pulse Units : 1 L/ P
Pulse Units at Max Flow Rate : 6.7 Hz
Reed Switch
Output Freq : 10 L/ P
Pulse Units Output Freq : 0.67 Hz
at max Flow Rate
Max Flow Rate ( L/ h) : 24000
Tampilkan Lebih Banyak