PT. Daya Teknik Meterindo Harco Glodok Lantai 5 Blok F7 Office: Jl. Hayam Wuruk No. 2-5 Jakarta Barat, DKI Jakarta, 11180 Phone: (021) 2268-7062 HP: 0813-1516-6062; 0812-8222-5340; 0821-2214-8707 Email: [email protected] Up. Irwan Pangaribuan
SENSUS FLOWMETER DN 200 FOR HOT WATER
Water Meter
WP-Dynamic
Flow Sensor For Hot Water up to 130° C
DN 200
Flow Sensor Rate Pressure PN 40
Technical Data
Performance Data WP-Dynamic 130° C
Nominal Diameter : DN 200
Qmax : 500 m³ / h
Maximum peak flow
once lifetime 24h Qmax
or 5 min. 1.2 x Qmax
Qn-Continuous Flow ( ± 2% ) : 250 m³ / h
Qt-Transitional Flow ( ± 2% ) : 20 m³ / h
Qmin-Minimum Flow ( ± 5% ) : 8 m³ / h
Starting Flow : 2.0 m³ / h
Performance data table according to PTB-A22 spesification class B
Diameter Nominal DN : 200 mm
Size of meter ( acc. to PTB-A-22) Qn : 250
Qmax-Maximum peak flow short time : 500 m³ / h
Qn-Continuous Flow ( ± 3% ) : 250 m³ / h
Qt-Transitional Flow ( ± 3% ) : 37.5 m³ / h
Qmin-Minimum Flow ( ± 3% ) : 10.0 m³ / h